Falling Dart Impact Tester

Machine Features:-

This tester is applicable in energy test that causes plastic films and foils to fail under specified conditions of impact of a free-falling dart. This energy is expressed in terms of the weight of the dart falling from a specified height which would result in 50% failure of specimens tested.

1. Characteristics Compatible with state and international standards.
Novelty mechanical sculpt, considerate design.
Two test methods integration: A & B.
Special lighting design, easy to observe.
Micro-computer processes test results.
Intelligent test enhances test efficiency.
Pneumatic clamping and releasing decrease test time and errors.
Test procedure requires no manual drawing and mark, data and parameters are displayed by LCD.
System identifies, calculates test data automatically, requires no manual intervention.
Test stops automatically, results are displayed by multifold units, micro-printer prints results.


2. Principle At the beginning of the test, choose a test method, estimate an initial mass and ^m. Test, if the first specimen is failure, decrease the mass of the falling dart by decreasing poise of ^m. If the first specimen is not failure, add the mass of the falling dart by increasing poise of ^m. Test as the same. In brief, increase or decrease the ^m according to whether the former specimen is failure or not. After 20 specimens, calculate the total number of failure specimens N. If N equals to 10, test over. If N is less than 10, add specimen and continue to test until N is equal to 10. If N is more than 10, add specimen and continue the test until the number of non-failure specimen is 10. Then calculate the test results according to special formula.

3. Operation demo Power on -> choose test method -> estimate initial impact mass and ^m -> increase or decrease the ^m according to impact result -> system calculates automatically -> estimate whether the results satisfy the condition of stopping -> display test results -> print test results -> test over

4. Technical data Test method: A or B
Test range: Method A: 50 - 2000g Method B: 300 - 2000g
Test accuracy: 0.1g (0.1J)
Test condition: 23C 50%RH (Standard)
Specimen clamping: Pneumatic
Specimen size: > 150mm x 150mm
Power: AC 220V 50Hz
Net weight: 70kg
Dimension: Method A: 500(L)mm x 450(D)mm x 1320(H)mm
Method B: 500(L)mm x 450(D)mm x 2160(H)mm


5. Standard GB 9639, ASTM D1709

6. Standard configuration Method A

7. Optional configuration Method B

Note: Users provide gas resources for themselves.