| 1. Characteristics |
Mechanical test method, without restriction of testing
materials.
Testing resolution up to 0.1 um.
Contacting area and pressure between testing head
and specimen conform to the relative standards strictly.
Special configuration design guarantee the parallel of
the upper and lower test surfaces.
Method for adding weight realize the non-standards testes.
LCD displays test parameters, operation button friendly design.
Settable test modes of manual and automatic. Statistic and print test results automatically.
Compatible with ISO, ASTM and multifold test standards for specimen thickness.
|
| 2. Structure |
This tester is made up with control system, test system, print and output system. Test system test specimens
and output electrical signal. Control system is applied to setting and modification of parameters, signal
processing, results displaying and so on. Output system’s function is to print out the results.
|
| 3. Principle |
This tester employs the most advanced technology in the world, to guarantee the accuracy of the test results
and high consistency of several test results. Easy operation is approximately automatic, decreasing the
influence to test results caused by manual factors. Print out test results of single test. Statistic, analyze, and
print out test results of batch of tests. Contacting area, test pressure, and moving speed confirm to relative
standards strictly.
|
| 4. Technical data |
Test range: 0 - 2mm (normal)
Resolution: 0.1um
Test speed: 10 times/min (adjustable)
Test pressure: 17.5 +/- 1kPa (50 +/- 1kPa) (normal)
Contacting area: 50mm2 (200mm2)
Power: AC 220V 50Hz
Power consumption: 50W
Dimension: 300(L)mm x 275(D)mm x 300(H)mm
Net weight: 33kg
|
| 5. Standard |
ASTM D645, ASTM D374, ASTM D1777, ISO 534, ISO 3034, ISO 4593
|
| 6. Operation demo |
Power on -> set parameters -> place specimen -> start test -> test over -> print test results ->test stop
|
| 7. Configuration |
Standard:
Mainframe, calibration panel.
Optional:
Software, adding weight poise and panel.
|
|